用于水提取的固相萃取盘
Biotage 是磁盘 SPE 技术的领导者。 Atlantic® SPE 盘能够处理大量样品的提取,同时轻松保持快速流速,是饮用水、地下水和废水样品提取的**选择。
Atlantic® SPE 磁盘与手动和高度控制的自动化处理系统兼容,是当今市场上**获得自动化认证的磁盘。
订货信息:
Atlantic® SPE 固相萃取膜和预过滤器
货号 | 描述 | 包装 |
47-2346-11 | Atlantic® 8270 One Pass Disks, 47 mm | 24 |
47-2346-02 | Atlantic® C-18 Disks, 47 mm | 24 |
47-2346-14 | Atlantic® Disk, C-18HC, 8 mm | 16 |
47-2346-16 | Atlantic® Disk, Fiber, 8 mm | 16 |
47-2346-15 | Atlantic® Disk, HLB-H, 8 mm | 16 |
47-2346-06 | Atlantic® DVB Disks, 47 mm | 24 |
FFAP-47-HT | Atlantic® Fast Flow Pre-Filter, 47 mm, Coarse 5.0 µm | 50 |
FFAP-100-HS5 | Atlantic® Fast Flow Pre-Filter, 90 mm, Coarse 5.0 µm | 50 |
FFAP-100-HS1 | Atlantic® Fast Flow Pre-Filter, 90 mm, Fine 1.0 µm | 50 |
47-2346-13 | Atlantic® High Capacity C18 Disks, 47 mm | 24 |
47-2346-10 | Atlantic® HLB-H Disks, 47 mm | 24 |
47-2346-08 | Atlantic® HLB-L Disks, 47 mm | 40 |
47-2346-09 | Atlantic® HLB-M Disks, 47 mm | 30 |
This silica based C18 is end-capped to eliminate unpredictable secondary interactions with unreacted silanols. This reversed-phase media can be used for EPA Method 525.2 along with other drinking and wastewater methods.
Atlantic® High Capacity C18 SPE Disks provide added retention per disk for improved recovery of compounds that have weaker interactions with C18 media. Much like the original Atlantic C18 disk, the Atlantic High Capacity uses end-capped C18 to eliminate unpredictable secondary interactions with unreacted silanols. The disk can be used for drinking water applications such as EPA Method 525.2
Users have experienced higher recoveries for compounds such as dimethoate, 2,6-DNT, and 2,4-DNT. In the specific case of caffeine, a compound used as a drinking water tracer, recoveries more than doubled over standard C18 disks.
This disk contains media with 3 analyte retention mechanisms that significantly simplify the extraction process with the benefit of reduced labor, faster extraction times and elimination of high pH precipitates. This multi-mode disk chemistry enables the retention of over 100 target semi-volatile compounds with a sample pH of 2. Now acidic, neutral and basic analytes can be retained in a single water extraction step using this 47 mm disk. For extremely hydrophilic compounds, the optional Carbon Cartridge is placed after the One Pass disk to scavenge the sample effluent for light-end semi-volatile organics (LSVO). In this configuration all classes of compounds from EPA Method 8270/625 are automatically captured, eluted off the media and ready for drying and concentration.
The DVB (divinylbenzene) polymer is a pH independent reversed-phase media that is listed for use in the EPA drinking water method for a full suite of analytes, EPA Method 525.3.
The polymeric HLB (hydrophilic/Lipophilic Balanced) media in this disk comes in low, medium and high capacity formulations. These disks can be used for drinking and wastewater applications. Common applications include semi-volatile organic analysis and EPA Method 1694 (pharmaceuticals and personal care products), endocrine disruptors, and other emerging contaminants in wastewater and drinking water.
For use with the Atlantic SPE Disk, the Atlantic Prefilter increases sample flow rate without compromising recoveries. Perfect for dirty samples with lots of particulates, the Atlantic prefilter will accelerate sample throughput, and enables reproducible recoveries. These prefilters are “Certified for Automation” designed specifically for use with the Biotage® Horizon 5000 system.
These prefilters have proven to be effective in handling highly particulate laden aqueous samples. They are specifically designed and certified for use with the EZ Flow Disk Holder on the Biotage® Horizon 5000 system and are available in a 1 micron and 5 micron size.